Multi Platform RF Device
A State-of-Art device that widens the treatment possibilities equipped with the needle tip with the industry’s first drug delivery mechanism.

Widely applicable to various skin types and symptoms
Product Features
Coated needles cause Zero thermal damage to the epidermis Easy to receive treatment with short downtime even with high power output
Allowing the medication to infiltrate the needle hole evenly Equipped with Drug delivery mechanism that can produce synergetic effect with medication
In acne scar treatment and skin rejuvenation therapy, there is a high demand from both physicians and patients for the use of medication in combination. However, conventional treatments use equipments that do not take efficiency of into account. POTENZA’s needle tip with pumping mechanism allows even distribution of medication into the needle hole, which contributes to patient-centered treatment that pursues drug synergy.
Pumping tip with drug delivery mechanism
The pumping tip is equipped with a unique mechanism that applies negative pressure to the skin at the time of puncture, followed by positive pressure to ensure even distribution of the medication.
Usefulness of the Pumping tip
Wound-healing by microneedling with RF energy and Synergetic effect when used in combination with PLLA formulation
PLLA formulation has tended to be avoided due to the risk of granuloma. However, McCoom7, developed exclusively for POTENZA can significantly reduce the risk due to its fine particle formulation.
PLLA (Poly-L-Lactic-Acid) is a biodegradable polymer with a proven track record in the medical field. It is a component that breaks down into water and carbon dioxide inside the human body over several months to approximately two years. When injected subcutaneously, it promotes the production of dermal collagen and does not cause rejection or immune reaction in the human body. We do not recommend using any PLLA formulations other than McCoom7 for use in POTENZA, as they have larger molecular weights .
New approach to melasma and red skin based on a new theory
Rosacea dermatitis treatment that does not destroy melanocytes nor create melasma
Conventional toning therapy aims to improve melasma by gently stimulating pigment discharge at low power, and while some patients may experience high efficacy, others may experience a risk of melasma worsening regardless of the doctor’s experience. POTENZA’s melasma approach is a completely new approach that aims to “create a melasma-free skin” by suppressing “melanogenesis” that causes inflammation, opening up the possibility of melasma improvement for patients who have had no success with conventional treatments.
Approach to red skin by inhibition of angiogenesis(rosacea dermatitis, rosacea-like dermatitis)
To develop POTENZA, we focused on the relationship between keratinocyte proliferation and angiogenesis,and have identified the parameters(*) to act on VEGF-related factors that promote keratinocyte proliferation. This identification has overturned the conventional concept of laser treatment that recurrence is unavoidable even after vascular obliteration (burnout) treatment. With revolutionary RF treatment device POTENZA, you will be able to offer your patients a new treatment method for flushing(rosacea and red face) while also preventing the recurrence by inhibiting angiogenesis.
Wide variety of tips and modes expands therapeutic areas.
Treatment areas can be expanded by simply replacing the 13 different tips.
A wide variation in needle lengths, number of needles, and insulation coating methods support physician‘s effective treatment according to each case.

Select from 4 modes to support optimal treatment method
POTENZA’s flexible design allows physicians to freely select the combination of bipolar/monopolar and 1MHz/2MHz output methods to fully utilize the characteristics of RF. POTENZA enables you to perform an optimal treatment in consideration of the patient’s skin condition and the expected effects.
Main Specifications
RF TYPE | Bipolar/Monopolar |
Power | Max 50 watt |
Frequency | 1Mhz~2Mhz |
Repetition Rate | 0.5~3.0sec(0.1sec/step) |
Needle Thickness | 0.25mm |
Adjustable Depth | 0.5mm~4.0mm(0.25mm/step) |
Treatment Duration | 5~990ms(5ms/step) |
Electrical Power | 100~240V, 50/60Hz, 500VA |
Dimention | 503.2×365.6×316mm(incl. cable stand:550×701×366mm) |
Weight | Approx.9.5kg |
Cart(optional) | Type1:478×482×967mm, 32.26kg Type2:478×457×833mm, 22.2kg |